Lmk3 (BH) -0.66 III Low Voltage Transformer CT

Product Details
Customization: Available
Application: Instrument, Measuring and Protection
Type: Current Transformer
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (23)
  • Lmk3 (BH) -0.66 III Low Voltage Transformer CT
  • Lmk3 (BH) -0.66 III Low Voltage Transformer CT
  • Lmk3 (BH) -0.66 III Low Voltage Transformer CT
  • Lmk3 (BH) -0.66 III Low Voltage Transformer CT
  • Lmk3 (BH) -0.66 III Low Voltage Transformer CT
  • Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Packaging & Shipping
  • Our Advantages
  • Our Team and exhibition
  • Our Workshop
Overview

Basic Info.

Model NO.
BH-0.66
Phase
Single
Operation Condition
Indoor
Usage
Protection, Measurement
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Epoxy Resin
Installation
Busbar Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Metering Class
0.2s, 0.2, 0.5s, 0.5
Rated Voltage
660V
Standard
IEC61869-2
Rated Frequency
50Hz or 60Hz
Transport Package
Standard Export Box
Specification
380*240*470mm
Trademark
Lokedl
Origin
China
HS Code
8504311000
Production Capacity
50000 Pieces/Year

Product Description

Product Description

Low voltage indoor Current Transformer
· Indoor epoxy resin current transformer or indoor plastic casing current transformer
· Single phase, two phase or three phase.
· Rated voltage: 0.66kV
· Metering class for CT: 0.2S, 0.2,0.5, 0.5S
· Standard: IEC61869-2
· Type name: BH-0.66, MSQ-0.66, LMK1-0.66

This indoor dry type current transformer is used in 0.66kV, 0.75kV. power system, for measuring and protection.
It has been used in cubicle switchgear or in bay-installed switching stations.
The current transformer is made from high temperature indoor epoxy resin, amorphous alloy core for metering and high quality inside core for protection, primary and secondary use pure electrolytic copper.

Standard
IEC standards IEC 61869. IEEE C57.13

Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Standard Sizes
specification Dimensions Perforation Size Installation
Notes
W H D a e
50III 91 127 58 33 55 D
60III 100 145 58 33 65 D
80III 100 168 58 33 85 D
100III 100 196 55 32 102 D
100*50III 124 196 58 55 102 D
120*50III 124 220 58 55 125 D
130*50III 125 230 58 55 135 D

Detailed Photos

Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Lmk3 (BH) -0.66 III Low Voltage Transformer CT

 

Product Parameters

    
Specifications 50III 60III 80III 100III 100*50III 120*50III 130*50III
Max busbar/QTY 50*10/1-2 60*10/1-2 80*10/1-2 100*10/1-2 100*10/2-3 120*10/2-3 130*10/2-3
Accuracy 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5
Rated primary/secondary current (A) Rated Burden
200/5   2.5                        
250/5   5                        
300/5   5   5                    
400/5   5   5   5                
500/5   10   10   10   10            
600/5 5 10 5 10   10   10   10        
700(800)/5 5 10 5 10 5 10 5 10 5 10 5 10 5 10
1000/5 10 15 10 15 10 15 10 15 10 15 10 15 10 15
1200(1250)/5     10 15 10 15 10 15 10 15 10 15 10 15
1500/5     15 20 15 20 15 20 15 20 15 20 15 20
2000/5     20 30 20 30 20 30 20 30 20 30 20 30
2500/5         20 30 20 30 20 30 20 30 20 30
3000/5         20 30 20 30 20 30 20 30 20 30
4000/5             20 30 20 30 20 30 20 30
5000/5                 20 30 20 30 20 30
6000/5                         20 30
 
Specifications 50III 60III 80III 100III 100*50III 120*50III 130*50III
Max busbar/QTY 50*10/1-2 60*10/1-2 80*10/1-2 100*10/1-2 100*10/2-3 120*10/2-3 130*10/2-3
Accuracy 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5 0.2 0.5
Rated primary/secondary current (A) Rated Burden
200/1   2.5                        
250/1   5                        
300/1   5   5                    
400/1   5   5   5                
500/1   10   10   10   10            
600/1 5 10 5 10   10   10   10        
700(800)/1 5 10 5 10 5 10 5 10 5 10 5 10 5 10
1000/1 10 15 10 15 10 15 10 15 10 15 10 15 10 15
1200(1250)/1     10 15 10 15 10 15 10 15 10 15 10 15
1500/1     15 20 15 20 15 20 15 20 15 20 15 20
2000/1         20 30 20 30 20 30 20 30 20 30
2500/1         20 30 20 30 20 30 20 30 20 30
3000/1             20 30 20 30 20 30 20 30
4000/1                 20 30 20 30 20 30
5000/1                         20 30

Certifications

Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Lmk3 (BH) -0.66 III Low Voltage Transformer CT
 
Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Lmk3 (BH) -0.66 III Low Voltage Transformer CT

 

Packaging & Shipping

Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Lmk3 (BH) -0.66 III Low Voltage Transformer CT

 

Our Advantages

1. Premium Materials
High-Grade Cores: Precision-laminated silicon steel or nanocrystalline cores for minimal losses and high linearity.  
Robust Insulation: Epoxy resin designs ensure long-term stability in harsh environments.  

2. Superior Performance
Accuracy: Class 0.2/0.5 for metering, 5P/10P for protection, compliant with IEC 61869, 60044, IEEE, and ANSI standards.  
Wide Range: Supports 0.6kV-36kV systems, with custom ratios/frequency (50/60Hz).  
Low Thermal Rise: Optimized design reduces overheating, extending lifespan.  
EMC Immunity: Shields against electromagnetic interference for reliable signals.  

3. Service & Support
Custom Solutions: Tailored ratios, sizes, or connectors (e.g., DIN rail, IEC terminals).  
Global Certifications: IEC, CE, ISO, and local grid approvals.  
Lifelong Technical Aid: 24/7 support, installation guidance, and spare parts supply.  
Fast Delivery: Standard products in 2-4 weeks; expedited options for urgent needs.  

---  
Why Trust Us?
15+ years in power industry, serving 500+ clients worldwide.  
Rigorous testing 100% routine tests with reports provided.  
"Zero major failure" record since 2015.  

Need a quote or specs?
Contact us today for a responsive, no-obligation consultation.  

 

Our Team and exhibition

Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Lmk3 (BH) -0.66 III Low Voltage Transformer CT

 

Our Workshop

 
Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Lmk3 (BH) -0.66 III Low Voltage Transformer CT
 
Lmk3 (BH) -0.66 III Low Voltage Transformer CT
Lmk3 (BH) -0.66 III Low Voltage Transformer CT



FAQ

1. What customization options do you offer?
We provide tailored solutions based on your specific requirements, including adjustments to dimensions, performance specifications,
and other technical parameters. Contact us with your needs, and we'll confirm feasibility.  

2. How do I request a custom product?
Simply send us your detailed specifications (e.g., technical drawings, performance standards, or samples). Our team will evaluate and provide a solution within 2 business days.  

3. Are there minimum order quantities (MOQ) for customized products?  
MOQ depends on the complexity of customization. Standard products may have low MOQs, while highly specialized designs may require larger volumes. Discuss your needs with us for clarity.  

4. What's the lead time for custom orders?  
Lead times vary based on design complexity and order volume. Standard products ship in 2 weeks, while custom projects may take longer. We'll provide a timeline after reviewing your requirements.  

5. Can you meet international certifications/standards (IEC, CE, ISO, etc.)?
Yes, we comply with major international standards. Specify your certification requirements, and we'll ensure compliance.  

6. How do you ensure quality for custom products?
We conduct rigorous in-house testing and offer third-party inspections if needed. Prototypes can be provided for approval before mass production.  

7. What if I need technical support after purchase?
Our team provides lifelong technical assistance, including installation guides, troubleshooting, and spare parts support.  

8. Do you offer samples? Are they free?  
Samples are available for evaluation. Costs depend on product complexity-contact us for details.  

9. What's your payment terms for custom orders?
Standard terms include [T/T, L/C, etc.], with deposits required for custom projects. Terms are negotiable for long-term partnerships.  

10. How do you handle shipping and logistics?
We work with reliable global carriers (DHL, FedEx, sea freight, etc.) and handle customs documentation. Incoterms (EXW, FOB, CIF, CFR, etc.) can be negotiated.  

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now